pop02

বৃহস্পতিবার, ২২ জানুয়ারী, ২০১৫

Washing Machine

Washing Machine
Ø  Work: Color fastness to wash.

Ø  Subject: Color fastness to washing is the common quality parameter, which is considered very important from the point of view of consumers. This test determines the loss & change of color in the washing process by a consumer and the possible staining of other garments or lighter portion that may be washed with it.




Ø  Machine configuration & equipment:

v  Wash wheel

v  Standard reference detergents without Optical Brighteners – either ECE or AATCC
1993 as specified by the standards.

v  Multfibre Fabric

v  Stainless Steel Balls

v  Grade 3 Water

v  Washing pot




                                    Different parts of the M/C



Test Equipment




                                Work Stapes

ü  Sample are cut either in 4 x 10 cm size (ISO) or 5 x 10 cm for AATCC 61 1A or 5 x 15
            cm for other AATCC 61 methods.

ü  Sample and multifibre attach by stitch.

ü  Temperature rate will be 1.50C / min

ü  A wash liquor is prepared using Grade 3 water( with 400C), the appropriate detergent and additives. The detergents that are specified are the ECE standard reference
           detergent WOB and AATCC Standard Reference Detergent 1993 WOB.

ü  The Sample + multifibre is placed in the wash wheel pot(M/C temperature will 400C) containing wash liquor,
            with additives and steel balls as may be required. The wash wheel is then run for the
            appropriate time duration.
ü  After unload this will be wash at 400C in 100 ml normal water for 1 Min for two times.

ü  The Sample + multifibre dried in still air at temperatures not exceeding
            60°C. Once dry and conditioned, assessment is carried out.

ü  When yarn of fibres are to be tested yarn/fibre weight and multifabric weight well be equal.





               Assessment / Results and Interpretation

ü  Change in shade – loss of colour or tone as compared to the original unwashed
Sample.


Test result :
Gradeing by grey scale or data color (Spectrum)
Grades :
5 – Very good
4 – Good
3 –Fair
2 –Modarote
1 –Poor
0 –Very poor
Grade 3 will be allowed but lower than are not allowed



Summary of Test Conditions – ISO and AATCC methods

Test Method
Test No.
Temp.
(° C) ± 2°C
Soap/
Detergent (g/l)
Na2CO3
(Sodium carbonate)
(anhydrous)
(g/l)
NaOCl
1%
(Sodium hydroclorate)
(cc/l)
NaBO3
4H O
(g/l)
Liquor
volume (ml)
or liquor
ratio
Steel  balls
Time
(min,)

ISO 105 CO6 -1994
A1S
A1M
A2S
40
40
40

4
pH
….


-

None
None
1

150

10
30
45
30

B1S
B1M
B2S
50
50
50

4
….
….
….

-
None
None
1

150
25
50
25
30
45
30
C1S
C1M
C2S
60
60
60

4

10.5±0.1

-
None
None
1

50
25
50
25
30
45
30
D1S
D1M
D2S
D3S
D3M
70
70
70
70
70

4


10.5±0.1
None
None
None
0.015
0.015
None
None
1
None
None


50
25
100
25
25
100
30
45
30
30
45

E1S
E2S
95
95
4
10.5±0.1
-
None
1
50
25
30




কোন মন্তব্য নেই: